Gostaria de saber se os resultados deste autoteste SMART indicam uma falha na unidade, esta é a única unidade que apresenta 'concluído: leia falha' nos resultados.
# smartctl -l selftest /dev/sde
smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF READ SMART DATA SECTION ===
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed: read failure 90% 8981 976642822
# 2 Extended offline Aborted by host 90% 8981 -
# 3 Extended offline Completed: read failure 90% 8981 976642822
# 4 Extended offline Interrupted (host reset) 90% 8977 -
# 5 Extended offline Completed without error 00% 410 -
A unidade ainda não mostra sinais de falha, além da saída desse autoteste SMART. Essa é a saída de uma unidade diferente no mesmo sistema que está executando atualmente um autoteste SMART
# smartctl -l selftest /dev/sdc
smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF READ SMART DATA SECTION ===
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Self-test routine in progress 30% 15859 -
# 2 Extended offline Completed without error 00% 9431 -
# 3 Extended offline Completed without error 00% 8368 -
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 1
3 Spin_Up_Time 0x0027 176 175 021 Pre-fail Always - 4183
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 48
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
7 Seek_Error_Rate 0x002e 100 253 000 Old_age Always - 0
9 Power_On_Hours 0x0032 088 088 000 Old_age Always - 8982
10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always - 0
11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 46
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 34
193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 13
194 Temperature_Celsius 0x0022 111 101 000 Old_age Always - 36
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 1
198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 1
200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 2
smartctl -a /dev/sde
e publicasse a seção rotuladaSMART Attributes Data Structure
que contém contadores brutos. Em particular, o primeiro delesRaw_Read_Error_Rate
é o melhor indicador de "unidade defeituosa" (e provavelmente será! 0 no seu caso).